PRODIK-T 25

Automatically tuned impedance matching network for low power applications

 

Operating frequency:   13.56 MHz
Nominal power:   1.5 kW
Max. power:   depends on the load impedance
Max. load current:   25 A
Coolant:   forced air
Input connector:   7/16 jack
Output connector:   7/16 jack
Control system:   local via CAN-Bus
Interfaces:   RS 232 or Profibus
 

 

Dimensioned drawing: 


PRODIK-T 50

Automatically tuned impedance matching network

 

Operating frequency:   13.56 MHz
Nominal power:   5 kW
Max. power:   depends on the load impedance
Max. load current:   50 A
Coolant:   water
Input connector:   7/16 jack, 7/8'' EIA (optional)
Output connector:   7/8'' EIA
Control system:   local via CAN-Bus
Interfaces:   RS 232 or Profibus
 

Dimensioned drawing: 

PRODIK-T 50/C

Automatically tuned impedance matching network with cylindric design (for round cathodes)

 

Operating frequency:   13.56 MHz
Nominal power:   5 kW
Max. power:   depends on the load impedance
Max. load current:   50 A
Coolant:   water
Input connector:   7/16 jack, 7/8'' EIA (optional)
Output connector:   7/8'' EIA
Control system:   local via CAN-Bus
Interfaces:   RS 232 or Profibus
 

Dimensioned drawing: 

( Ansicht von oben )
( Seitenansicht )

PRODIK-T 75

Automatically tuned impedance matching network for medium load currents 

Operating frequency:   13.56 MHz
Nominal power:   7 kW
Max. power:   depends on the load impedance
Max. load current:   75 A
Coolant:   water
Input connector:   7/8'' EIA, jack (optional)
Output connector:   customized
Control system:   local via CAN-Bus
Interfaces:   RS 232 or Profibus

PRODIK-T 130

Automatically tuned impedance matching network for high load currents

Operating frequency:   13.56 MHz
Nominal power:   10 kW
Max. power:   depends on the load impedance
Max. load current:   130 A
Coolant:   water
Input connector:   7/8'' EIA, jack (optional)
Output connector:   customized
Control system:   local via CAN-Bus
Interfaces:   RS 232 or Profibus
 

Dimensioned drawing: 


( Seitenansicht )
( Vorderansicht )

PRODIK-T 160

Automatically tuned impedance matching network for high load currents

Operating frequency:   13.56 MHz
Nominal power:   15 kW
Max. power:   depends on the load impedance
Max. load current:   160 A
Coolant:   water
Input connector:   7/8'' EIA, jack (optional)
Output connector:   special coaxial connector, adaptable, water-cooled (optional)
Control system:   local via CAN-Bus
Interfaces:   RS 232 or Profibus
 

Dimensioned drawing: 

PRODIK-T 300

Automatically tuned impedance matching network for very high load currents

 

Operating frequency:   13.56 MHz
Nominal power:   30 kW
Max. power:   depends on the load impedance
Max. load current:   300 A
Coolant:   water
Input connector:   1 5/8''
Output connector:   customized
Control system:   local via CAN-Bus
Interfaces:   RS 232 or Profibus
 

Dimensioned drawing:

PRODIK-N 35

Automatically tuned impedance matching network (N-network)

Operating frequency:   13.56 MHz
Nominal power:   3 kW
Max. power:   depends on the load impedance
Max. load current:   35 A
Coolant:   water
Input connector:   7/16 jack
Output connector:   7/8'' EIA
Control system:   local via CAN-Bus
Interfaces:   RS 232 or Profibus
 

Dimensioned drawing: 

( side view  )
( front view )